¡¡¡¡The surface materials of high temperature series labels are ceramic¡¢PI and aluminum foil .The labels can be used for the tracking of automobile engine production process control and internal components traceability.The label can be sticked in the process of  engine die-casting¡¢heat treatment¡¢mechanical processing¡¢immersion¡¢assembly and so on. The label can be used for the labeling of glass and metal manufacture process. The label can be used for high temperature resistant labels in iron and steel ¡¢casting and aluminum industry. The material match with TLB series specific ribbon can print high definition of barcode and image on-site.
-----------------------------------------------------------------------------------------------------------------------------------------------------
Features£º
¡ñ¡¡Excellent high temperature resistance¡¢chemical erosion resistance
¡ñ¡¡Strong mucosity and suitable for different printing methods
¡ñ¡¡Conform to ROHS Directive
-----------------------------------------------------------------------------------------------------------------------------------------------------
Construction£º              
-----------------------------------------------------------------------------------------------------------------------------------------------------
Type Material of Face Sheet Features Thickness of Face Sheet [um] Adhesive Application Fields
Type Thickness£¨um£©
TLB5200 PET Resist 200¡æ 50 Acrylic 25 Automobiles£¬steel£¬ electronic industries
TLB5200A PET Resist 200¡æ 50 Acrylic 25 Automobiles£¬steel£¬ electronic industries
TLB5300 PI Resist 300¡æ 25 Acrylic 25 Printed circuit board ¡¢Iron and Steel
TLB5300A PI Resist 300¡æ 25 Acrylic 25 Printed circuit board ¡¢Iron and Steel
TLB5301 PI Resist 300¡æ 50 Acrylic 25 Printed circuit board ¡¢Iron and Steel
TLB5301A PI Resist 300¡æ 50 Acrylic 25 Printed circuit board ¡¢Iron and Steel
TLB5350 PI Resist 350¡æ 25 Organosilicon 25 Printed circuit board ¡¢Iron and Steel
TLB5350A PI Resist 350¡æ 25 Organosilicon 25 Printed circuit board ¡¢Iron and Steel
TLB5351 PI Resist 350¡æ 50 Organosilicon 25 Printed circuit board ¡¢Iron and Steel
TLB5351A PI Resist 350¡æ 50 Organosilicon 25 Printed circuit board ¡¢Iron and Steel
TLB5500 Aluminum foil Resist 550¡æ 80 special glue 25 Iron and Steel
TLB5500A Aluminum foil Resist 550¡æ 80 special glue 25 Iron and Steel
TLB5600 Ceramic Resist 600¡æ 50 special glue 25 Glass¡¢Iron and Steel¡¢engine
TLB5800 Ceramic Resist 800¡æ 50 special glue 25 Ceramic¡¢Iron and Steel¡¢Glass
TLB5L00 Ceramic Resist 1200¡æ 50 special glue 25 Ceramic¡¢Iron and Steel
-----------------------------------------------------------------------------------------------------------------------------------------------------
Application£º
-----------------------------------------------------------------------------------------------------------------------------------------------------
¡ñ¡¡Machinery and equipment management information labels
¡ñ¡¡High temperature resistant labels in automotive and electronic industry
¡ñ¡¡PCB soldering
¡ñ¡¡Heat treatment process tracking of metal parts in automotive and Iron and Steel industries
-----------------------------------------------------------------------------------------------------------------------------------------------------
Property£º
-----------------------------------------------------------------------------------------------------------------------------------------------------
Properties25 Test Method Typical Results
  ASTM D1000  
Thickness Face sheet 0.025mm¡«0.080mm
Adhesive 0.025mm
- Total 0.050mm¡«0.105mm
Initial adhesion GB-4852 J. Dow 3#
Insulation ASTM D1000 6000 V
-----------------------------------------------------------------------------------------------------------------------------------------------------
Durability Testing£º
-----------------------------------------------------------------------------------------------------------------------------------------------------
Test Method£ºUse Zebra printer and TLB121 ribbon or TLB22 ribbon for sample printing. Before testing£¬put the sample on the aluminum plate for 24 hours. If no specific instructions, the follwing test result is suitable for TLB121 ribbon and TLB22 ribbon.
Properties Test Method Typical Results
Max. temperature 3 days at 1200¡æ No visible effect
Min. temperature 3 days at -20¡æ No visible effect
Humidity resistance 3 days at 37¡æ£¬95% RH No visible effect
UV Light resistance 3 days in UV Sunlight™-100 No visible effect
Weatherability 3 days in Xenon Arc Weatherometer
(ASTM G 26)
No visible effect
Salt Fog Resistance 3 days in 5% salt fog solution
chamber (ASTM B 117)
No visible effect
-----------------------------------------------------------------------------------------------------------------------------------------------------
Chemical Testing£º
-----------------------------------------------------------------------------------------------------------------------------------------------------
Test Method£ºUse Zebra printer and TLB121 ribbon or TLB22 ribbon for sample printing. Before testing£¬put the sample on the aluminum plate for 24 hours .The test goes ahead at room temperature. Every 30 minutes put the sample into designated Chemical Solution for 10 minutes. Repeat 5 times. The last time, after soaking£¬use cotton ball with test solution to clean the surface of the sample for 10 times.
Chemical Solution Visual Changes
Label TLB121 TLB22
Freon-® TMS No visible effect No visible effect No visible effect
Isopropyl Alcohol No visible effect No visible effect No visible effect
Inorganic Alcohol No visible effect No visible effect No visible effect
JP-8 Jet Fuel No visible effect No visible effect No visible effect
ASTM 3 oil No visible effect No visible effect No visible effect
Mil 5606 oil No visible effect No visible effect No visible effect
Gasoline No visible effect No visible effect No visible effect
Skydrol®-500B-4 No visible effect No visible effect No visible effect
Super Agitene-® No visible effect No visible effect No visible effect
BIOACT-EC-7-™ metallics No visible effect No visible effect No visible effect
Deionized water No visible effect No visible effect No visible effect
3% Alconox-® Detergent No visible effect No visible effect No visible effect
10% Sodium Hydroxide solution No visible effect No visible effect No visible effect
10% Sulfuric Acid solution No visible effect No visible effect No visible effect
¡ùThe above data sheet and test results are only for reference. Before using, please test them in actual use. Toplabel will not responsible for any loss caused by operating error and improper use. If you need more information£¬please phone our technique department. The company will regularly update the above technical information.

 
 